[Diagnose B1577] [System Properties] Version = 1.0.0.0 / 9.0.1.2 Serial Number = PLVTyTxPcn169qyaqBMSsf Mac Addr 1 = 0C-86-29-73-7F-FB [IPv4 Configuration] Dhcp = true Addr = Subnet Mask = Default Gateway = Primary Dns = Secondary Dns = [Fallback Ipv4] Addr = 10.7.4.11 Subnet Mask = 255.255.255.0 Default Gateway = 10.7.4.1 Primary Dns = 8.8.8.8 Secondary Dns = 8.8.4.4 [Current Ipv4] Addr = 10.7.4.105 Subnet Mask = 255.255.255.0 Default Gateway = 10.7.4.250 Primary Dns = 10.2.2.2 Secondary Dns = 10.2.2.30 [System Configuration] Ocpp Mode = Full Free Tag = RFID_Disabled Modbus Energy Meter = true Restart Tx After Power Loss = true Restart Tag = POWER_LOSS_TAG Attached Cable = false Indoor = true Ev41 = Disabled Chp Input = Load shedding 7A/13A Dn Behavior = Not used Dn Input = Night enable charge Dn Mode = Inclusive charge Dn Delay = 0 mn Station Limit = 64 A Blackout Timer = 5 s Fallback Setpoint Connectors 12 = 32 A Fallback Setpoint Connectors 34 = 32 A Pulse Weight 1 = 1 Wh Pulse Weight 2 = 1 Wh Connector Phase Rotation 1 = RST Connector Phase Rotation 2 = RST [System Inputs] Phase Number = 3 Coding Wheel = 32 A Pin Code = Off Day Night = Open Chp Input = Open Loop 1 = Open Loop 2 = Open [Web Server Configuration] Password Status = false [OCPP Server Configuration] Url = ws://10.7.4.24:8081 Identity = PLVTyTxPcn169qyaqBMSsf Login = Password = [OCPP Config] AllowOfflineTxForUnknownId = true AllowRestartTxAfterPowerLoss = true AuthorizationCacheEnabled = false AuthorizeRemoteTxRequests = false CentralSystemURL = ws://10.7.4.24:8081 ChargePointId = PLVTyTxPcn169qyaqBMSsf ChargeProfileMaxStackLevel = 5 ChargingScheduleAllowedChargingRateUnit = Current,Power ChargingScheduleMaxPeriods = 10 ClockAlignedDataInterval = 60 ConnectionTimeOut = 30 ConnectorPhaseRotation = 1.RST,2.NotApplicable,3.RST,4.NotApplicable ConnectorPhaseRotationMaxLength = 4 ConnectorSwitch3to1PhaseSupported = false EV41 = 0 FallbackSetpointConnectors12 = 32 FallbackSetpointConnectors34 = 32 GetConfigurationMaxKeys = 20 HeartbeatInterval = 60 LocalAuthListEnabled = false LocalAuthListMaxLength = 200 LocalAuthorizeOffline = false LocalPreAuthorize = true MaxChargingProfilesInstalled = 60 MaxEnergyOnInvalidId = 100000 MessageTimeout = 20 MeterValuesAlignedData = Energy.Active.Import.Register,Power.Active.Import MeterValuesAlignedDataMaxLength = 6 MeterValueSampleInterval = 60 MeterValuesSampledData = Energy.Active.Import.Register MeterValuesSampledDataMaxLength = 6 NumberOfConnectors = 4 ReserveConnectorZeroSupported = false ResetRetries = 1 RfidTagForRestartTxAfterPowerLoss = POWER_LOSS_TAG RfidTagFreeMode = RFID_Disabled RfidTagReaderEnabled = 0 SendLocalListMaxLength = 8 StopTransactionMaxMeterValues = 10 StopTransactionOnEVSideDisconnect = true StopTransactionOnInvalidId = true StopTxnAlignedData = StopTxnAlignedDataMaxLength = 1 StopTxnSampledData = Energy.Active.Import.Register StopTxnSampledDataMaxLength = 1 SupportedFeatureProfiles = Core,FirmwareManagement,LocalAuthListManagement,Reservation,SmartCharging,RemoteTrigger SupportedFileTransferProtocols = FTP,HTTP,HTTPS TransactionMessageAttempts = 5 TransactionMessageRetryInterval = 5 UnlockConnectorOnEVSideDisconnect = true WebSocketPingInterval = 120 [Modbus Meter 1] Product Code = ECR380D Version = 1.2.0 Energy = 6953 Wh Current 1 = 0.0 A Current 2 = 0.0 A Current 3 = 0.0 A Voltage 1 = 235 V Voltage 2 = 0 V Voltage 3 = 0 V Power 1 = 0 W Power 2 = 0 W Power 3 = 0 W Reactive Current 1 = 0.0 A Reactive Current 2 = 0.0 A Reactive Current 3 = 0.0 A [Modbus Meter 2] Product Code = ECR380D Version = 1.2.0 Energy = 1096 Wh Current 1 = 0.0 A Current 2 = 0.0 A Current 3 = 0.0 A Voltage 1 = 235 V Voltage 2 = 0 V Voltage 3 = 0 V Power 1 = 0 W Power 2 = 0 W Power 3 = 0 W Reactive Current 1 = 0.0 A Reactive Current 2 = 0.0 A Reactive Current 3 = 0.0 A [OCPP] Internet = OCPP OK Ocpp State = Accepted Online Charge point state = Available Charge point error = NoError Charge point vendor error = Connector 1 state = Available Connector 1 error = NoError Connector 1 vendor error = Connector 2 state = Available Connector 2 error = NoError Connector 2 vendor error = Connector 3 state = Available Connector 3 error = NoError Connector 3 vendor error = Connector 4 state = Available Connector 4 error = NoError Connector 4 vendor error = [Misc] Blackout Timer = 0 Update Status = No Update Date Time = 2025/04/23 14:02:52 [Diagnose B1237] [Informations] Version = 9.0.1.2 [Inputs] Coding_wheel_position = 6 Installation_phases = 3 Tariff = Open CHP_Input = Open Car_Detection_1 = Open Car_Detection_2 = Open Welded_1 = Open Welded_2 = Open [Outputs] CHP_Output = Off Spare_Output = Off Shunttrip_Output = Off [Socket_M3_1] EVSE_Contactor = Off EVSE_Lock = 0 EV_consumption_p1 = 0 A Cable = Not Connected Ctrl_pilot = Typical is_tri = true FP_State = A1 State = Unknown [Socket_M3_2] EVSE_Contactor = Off EVSE_Lock = 0 EV_consumption_p1 = 0 A Cable = Not Connected Ctrl_pilot = Typical is_tri = true FP_State = A1 State = Unknown [Socket_M2_1] EVSE_Contactor = Off EV_consumption_p1 = 0 A Cable = Open [Socket_M2_2] EVSE_Contactor = Off EV_consumption_p1 = 0 A Cable = Open [TIC] Activity = Inactive Data = Invalid (0) Mode = Unknown [Error] Rfid = No Error Mode3_1 = No Error Mode3_2 = No Error Mode2_1 = No Error Mode2_2 = No Error [Counters] Ch_duration_1 = 42 h Cycles_1 = 249 Ch_duration_2 = 15 h Cycles_2 = 70 Ch_duration_3 = 1147 h Cycles_3 = 443 Ch_duration_4 = 0 h Cycles_4 = 4